![]() ![]() For example, if you need the length of a beam two stories high, you simply aim and shoot points at each end of the beam and you are done – no ladder or scaffolding required. Reflectorless technology can also help makes job sites safer. Likewise, when trying to measure around an overhead beam or rafter, the prism pole can be inverted to allow measurement of a location unable to be seen directly with the red laser. In these cases, a prism and prism pole can be used to measure above the obstruction. A prism pole allows the instrument to reach places and measure points that can’t be achieved using a reflectorless method - for example, measuring around piles of building construction materials or other obstructions where a laser beam is unable to reach the desired point. When determining which method to use, consider the location and logistics of the area being measured. The reach of the laser beam varies between instruments – it ranges from 1,300 feet to 6,500 feet (400 to 2,000 meters). Instead, it uses a visible red laser beam that allows the user to layout or measure points from any surface that is able to reflect it. The reflectorless method does not use a prism. When the exact position is reached with the prism, the field software displays a confirmation message. The total station “tracks” the prism and continuously updates its position in the field software. ![]() The instrument is set up in the dirt off the building pad, and the person holding the prism pole, with the field controller attached, is guided by the field software to the correct location. A 360 degree prism can face any direction, whereas a standard round prism only has one face that must look toward the total station.Ĭonsider an application in which a stub-up needs to be located. ![]() Measurement to a typical 360 degree prism is roughly 5,000 feet (1500 meters), and measurement to a standard round prism can reach as far as 9,800 feet (3,000 meters). By measuring the prism’s position and knowing the precise angle and distance to that prism, the total station calculates the prism’s location or coordinates. With the prism method, the total station sends out invisible infrared waves that are reflected by the prism, which is typically attached to a pole. There are two ways the total station measures: using the traditional and still more common prism, or through reflectorless technology. However, how do you know what type of total station you need? Prism vs. If you’ve decided to invest in total station layout, you’ve taken a good first step toward providing BIM services. ![]()
0 Comments
Leave a Reply. |
AuthorWrite something about yourself. No need to be fancy, just an overview. ArchivesCategories |